PROCESS FIELD BUS

Application PROcess FIeld BUS is a standard for fieldbus communication in automation technology. PROcess FIeld BUS links controller or control systems with decentralized field devices (sensors and actuators) via a single bus cable on the field level. It also enables consistent data exchange with higher ranking communication systems. Consistency of PROcess FIeld BUS is enabled by utilizing a single, standardized, application-independent communication protocol (named PROcess FIeld BUS DP), which,

Technical Specifications

Application

PROcess FIeld BUS is a standard for fieldbus communication in automation technology. PROcess FIeld BUS links controller or control systems with decentralized field devices (sensors and actuators) via a single bus cable on the field level. It also enables consistent data exchange with higher ranking communication systems. Consistency of PROcess FIeld BUS is enabled by utilizing a single, standardized, application-independent communication protocol (named PROcess FIeld BUS DP), which, without any difference, supports fieldbus solutions both in factory and process automation as well as in motion control and safety-related tasks. To ensure correct interaction between the numerous devices of an automation solution, the basic device functions and services must match in regard to communication, functionality and industry sector solutions. This uniformity is achieved by means of “application profiles” which refer to device families or special industry sector requirements, e.g. process automation (PA Devices), Motion Control (PROFIdrive) or integration of HART devices. PROcess FIeld BUS DP is in the central position and carries communication data between a controller and field devices, preferably in Factory Automation (FA). PROcess FIeld BUS PA string is connected through a coupler or linking device to enable typical process automation (PA) applications, e.g. in a hazardous environments. The controller is connected to PROcess FIeld NET as system bus and interface to MES and ERP levels. PA segments can also be connected directly to PROcess FIeld NET using proxy technology.

Technical Data

  • Standard: Adapted to DIN 19245 & EN 50170
  • Operating Voltage: 250V (not for power installation)
  • Insulation Resistance : 5000 G x cm
  • Temperature Range: Flexing 12 x cable ø Fixed 6 x cable ø
  • Minimum Bending Radius: Flexing 12 x cable ø. Fixed installation 6 x cable ø
  • Test Voltage: 1500V
  • Flame Retardant: Complies ti IEC 60332-1-2

Cable Design Parameters

Variants Size Configuration Construction Application Sheath Colour Approx. Cable Dia. (mm)
Li2Y(St)CYv (TP) 02Y(St) CY DP 22 AWG x 1PR (0.32 Sq. mm) 1/0.64 mm ABC solid / Foam PE / PETP / AL. Mylar / ATC Braid 65% / PVC Outer sheath Fixed installation, indoor usage Violet 8.0
02Y(St) C11Y DP 22 AWG x 1PR (0.32 Sq. mm) 1/0.64 mm ABC solid / Foam PE / PETP / AL. Mylar / ATC Braid 65% / PUR Outer sheath Fixed installation, Industrial Area Black 8.0
02Y(St)CY DP Armoured 22 AWG x 1PR (0.32 Sq. mm) 1/0.64 mm ABC solid / Foam PE / PETP / AL. Mylar / ATC Braid 65% / PVC Inner sheath / GI armour wires / PVC Outer sheath Direct Burial Black (Outer) Violet (Inner) 13.0
PROcess FIeld BUS PA 02Y(St)CY PA Solid 18 AWG x 1PR (0.8 Sq. mm) 1/1.02 mm (1/18 AWG) ABC solid / Foam PE / PETP / AL. Mylar / ATC Braid 65% / PVC Outer sheath Fixed installation, indoor usage Blue 9.2
02Y(St)CY PA Armoured 18 AWG x 1PR (0.8 Sq. mm) 1/1.02 mm (1/18 AWG) ABC solid / Foam PE / PETP / AL. Mylar / ATC Braid 65% / PVC Inner sheath / GI armour wires / PVC Outer sheath Direct Burial Black (Outer) Blue (Inner) 14.0

Electrical Parameters

PROcess Fleld BUS DP
  • Conductor Resistance (Loop) at 20°C: 110 /km (Max.)
  • Mutual Capacitance: 35 nf/km (Max.)
  • Inductance: 0.65 mH/km (Nom.)
PROcess FIeld BUS PA
  • Conductor Resistance (Loop) at 20°C: 44 /km (Max.)
  • Mutual Capacitance : 55 nf/km (Max.)
  • Characteristic Impedance @ 31.25 kHz: 100 ± 15
  • Attenuation @ 39 Khz: ≤ 3 dB/km
  • Inductance: 0.65 mH/km (Nom.)
Frequency Characteristic Impedance (Ω) Attenuation (dB/100m)
9.6 kHz 270 ± 27 ≤ 0.25
38.4 kHz 185 ± 18.5 ≤ 0.40
4 MHz 150 ± 15 ≤ 2.2
16 MHz 150 ± 15 ≤ 4.2

PROcess FIeld BUS PA

  • Conductor Resistance (Loop) at 20°C: 44 /km (Max.)
  • Mutual Capacitance : 55 nf/km (Max.)
  • Characteristic Impedance @ 31.25 kHz: 100 ± 15
  • Attenuation @ 39 Khz: ≤ 3 dB/km
  • Inductance: 0.65 mH/km (Nom.)

Baud Rate vs Segment Length

Baud Rate (kbit/s) Segment Length (Meters) Segment Length (Feet)
9.6 1200 3940
19.2 1200 3940
45.45 1200 3940
93.75 1200 3940
187.5 1000 3280
500 400 1310
1500 200 656
3000 100 328
6000 100 328
12000 100 328
More Variants Available
  • PROcess FIeld BUS: DP and PA for flexible applications
  • PROcess FIeld BUS: DP and PA with steel braid
  • Halogen free variant with Low Smoke Zero Halogen (LSZH) outer sheath
Note
  • HART = Highway Addressable Remote Transducer
  • DP = Decentralized Peripherals
  • PA = Process Automation

Request Official Quotation

Direct B2B pricing with GST invoice & contractor quantity discounts.

Complementary Engineering Stock

Related & Compatible Products from RR Kabel

View All Catalog Items

BTC Insights

Guides related to this product

All articles
RR KabelBrand Comparisons
6 min read

RR Kabel vs Other Wire Brands: What Indian Industries Should Know Before Buying

RR Kabel vs Other Wire Brands: What Indian Industries Should Know Before Buying When it comes to industrial electrical systems, the selection of wire brands not just becomes a purchasing choice but an investment in safety, efficiency and sustainable use. Given the competition of cable manufacturers

Read the guide
Industrial Electrical CableCables & Wires
5 min read

How to Choose the Right Electrical Cable for Industrial Use?

How To Choose The Right Electrical Cable For Industrial Use? In the industrial sector, the electrical wiring of a factory, warehouse, or manufacturing facility can be considered the system of central nervous conduits in the plant. However, unlike electrical wiring found within the domestic space, in

Read the guide